1 / 1
| Ordering data | |
| Product type description | SRB-E-402EM |
| Article number (order number) | 103041198 |
| Mechanical data | |
| Mechanical lifetime, minimum | 10.000.000 Operations |
| Mounting | Snaps onto standard DIN rail to EN 60715 |
| Mechanical data - Connection technique | |
| Terminal designations | EN 60947-1 |
| Cable section, minimum | 0.25 mm² |
| Cable section, maximum | 2.5 mm² |
| Tightening torque of Clips | 0.5 Nm |
| Allowed type of cable | Solid single-wire, flexible |
| Terminal (mechanical) | Removable screw terminals |
| Mechanical data - Dimensions | |
| Length of sensor | 22.5 mm |
| Width of sensor | 98 mm |
| Height of sensor | 115 mm |
| Ambient conditions | |
| Degree of protection of the enclosure | IP40 |
| Degree of protection of the installation space | IP54 |
| Degree of protection of clips or terminals | IP20 |
| Ambient temperature | -25 ... +60°C |
| Storage and transport temperature | -40 ... +85 °C |
| Resistance to vibrations | 10...55 Hz, Amplitude 0.35 mm, + 15 % |
| Resistance to shock | 10 g/ 11 ms |
| Ambient conditions - insulation values | |
| Rated impulse withstand voltage Uimp | 4kV |
| Overvoltage category | III |
| Degree of pollution | 2 |